TUNNEL VENTILATION SYSTEMS

All systems are built according to NFPA 130 Standard, 250 °C – 1 h. Certified Heat Resistant material.
Also EMAK have F300 and F400 certificate for all of our fans axial. The System Fans are tested by Fan Performance Test Code ISO 5801 – TPE – TR 2003 02023 Y

ISTANBUL – DUDULLU BOSTANCI M8 LINE METRO STORAGE AREA,
(IN PROCESS)
Tunnel/ Platform EXF and INF fans
Car Park and  Administration Building’s Jet Fans

ANKARA METRO SYSTEM-M4 METROLINE (2015)
37 Pieces – 100 m3/s (2240 – 160 kW) – F400 / Tunnel Ventilation Fans (TVF)
35 Pieces – Various Jet Fans – F400
38 Pieces– Fire Dampers and complete MCC Electrical Control Systems

ANKARA KEÇİÖREN METRO SYSTEM-STATION FANS (2013)
3 Pieces – 12 m3/s (900 – 11 kW) – F400
2 Pieces – 12,5 m3/s (900 –15 kW) – F400
2 Pieces – 14 m3/s (1000 –15 kW) – F400
1 Pieces – 14 m3/s (1000 – 11 kW) – F400
5 Pieces – 17,4 m3/s (1000–18,5 kW) – F400
2 Pieces – 20 m3/s (1120–22 kW) – F400
3 Pieces – 18 m3/s (1120–18,5 kW) – F400

SIVAS DELIKTAS TUNNEL (2013)
2 Pieces – 62 m3/s (1800 – 160 kW) – F400

İZRAY (İzmir Metro System) (2011) Phase II–Part 1
6 Pieces – 22 m3/s (37 – 45 kW) – F300
4 Pieces – 30 m3/s (90 –110 kW) – F300
6 Pieces – 50 m3/s (110 –160 kW) – F300
2 Pieces – 70 m3/s (132 – 200 kW) – F300
4 Pieces – 100 m3/s (250 kW) – F400

GEORGIA–RİKOTİ TUNNEL (2011)
2 Pieces 105 m3/s (360.000 m3/h) – 200 kW – Tunnel Ventilation Fans
2 Pieces 105 m3/s (378.000 m3/h) – 250 kW – F400 (400 ºC – 2h) – Smoke Fans and Dampers

BURSARAY (Bursa / TURKEY) LRTS (2011) – Bölüm II – Phase 2 TVF FANS
Two pieces in total
2 X 120 m3/s (432.000 m3/h) – 250 kW Each Smoke Fans, Smoke Dampers, Silencers , Electric Control Panels with Frequency Drivers
Istanbul Metro System (Istanbul – TURKEY) (2010) – F400 (400 °C – 2h) Seyrantepe Fans
2 x (Total Capacity 64.500 m3/h)

İZRAY (İzmir City – Turkey) (2010) LRTS  Phase III – Part 1 TVF FANS
İZRAY TUNNEL FANS
2 Pieces 100 m3/s – 1250 Pa – 200 kW (250 °C – 1 h.)
3 Pieces 80 m3/s – 950 Pa – 132 kW (250 °C – 1 h.)
2 Pieces 50 m3/s – 1350 Pa – 110 kW (250 °C – 1 h.)

BURSARAY (Bursa / TURKEY) LRTS  (2006) – Phase II – Part 1 TVF FANS
2 Pieces 120 m3/s (432.000 m3/h) 355 kW–250 °C – 1 h.
1 Pieces 70 m3/s (252.000 m3/h) 132 kW – 250°C –1 h.
Each Smoke Fans, Smoke Dampers, Automation system, Silencers, Electric Control Panels with Frequency Drivers and Remote Operator Panels (Turn key Delivery)

Istanbul Metro System (2007 – 2008) Sishane Station – Peron Fans (Alsim – Alarko) F300 ( 300 °C – 1 h.)

Eskisehir LRTS  (2006) – 6 X POWER SUBSTATION PRESSURIZATION – BOMBARDIER

Istanbul Metro System (2005) Taksim – Kabatas Funicular System Project Peron Fans – F300

Bursaray LRTS SYSTEM(2003) – Peron Fans – BURSA City – F300

BURSARAY (Bursa City Turkey) LRTS  (2003) – TVF FANS – Phase 1 & Phase 2

Total 16 Pieces – 108 m3/s (390.000 m3/h – 250 kW) – 250 °C – 1 h.

Each Smoke Fans, Smoke Dampers, Automation system, Silencers, Electric Control Panels with FrequenceDrivers, Remote Operator Panels and SCADA Integration.

IZRAY (İzmir City – Turkey) LRTS System (2001) Phase 1. 250 °C – 1 h.

Smoke Fans, Smoke Dampers, Automation system, Silencers, Electric Control Panels with FrequenceDrivers, Remote Operator Panels and SCADA Integration.

IZRAY OTE FAN SYSTEM (Total Capacity 10 Pieces 50 m3/s – 55 kW ) – 250 °C – 1 h